PROGRAMMING STRINGS
21
3
- 5 -
Get value of Digital Output 3 Activation Event parameter in DIGITAL OUTPUT LINES folder:
Path: /IO/Out/Out2/Active
Shortcut: 28
Type: 1 (Enumeration)
Current Value:
2 (Entry 2 Partial Read)
The 'Get Parameter' programming string is:
GP<space>/IO/Out/Out2/Active<CR><LF>
The 'Get Shortcut' programming string is:
GS<space>28<CR><LF>
After entering the programming string, the reader responds with the message:
Y<space>2<CR><LF>
- 6 -
Get value of No Read String parameter in CODE DEFINITION folder:
Path: /Codes/NoReadStr
Shortcut: 9
Type: 3 (Binary String)
Current Value: Empty string
The 'Get Parameter' programming string is:
GP<space>/Codes/NoReadStr<CR><LF>
The 'Get Shortcut' programming string is:
GS<space>9<CR><LF>
After entering the programming string, the reader responds with the message:
Y<space>0<CR><LF>