PROGRAMMING STRINGS
3
The 'Restore Default Configuration' programming command must have the
following format:
SD<space>DEFNUM<CR><LF>
Where:
• SD:
Restore Default configuration command
• DEFNUM:
Default configuration number. The only possible value is
currently:
0 = Factory Default
After entering this command, the device responds with the proper reply message and
then waits for one or more programming strings.
If the programming is correct, the device updates the configuration and confirms with
the following message:
Y<space>DEFNUM<CR><LF>
Where:
• DEFNUM:
Default
If programming contents are wrong (i.e. a typing error in the file) or due to a
transmission error, the device replies with the following message:
N<space>ERRCODE<CR><LF>
Where:
• ERRCODE:
Error Code (signed DEC value)
The complete Error Codes table is provided in the Paragraph 5.3.
WARNING
This programming command will be applied on all Configuration and
Environmental parameters. Refer to the Genius™ Help On Line of the
selected device for further details.