2KN FAMILY AND DS4800
4
PARAMETER COMPLETE PATH SHC PT VALUE
Heartbeat
Terminator String
/Comms
/SerMain/HeartbeatM
/TerminatorM
5078 Length: 0 to 128
MAIN SERIAL PORT / LINE PARAMETERS
Main Port
Communication
mode
/Comms
/SerMain/Line
/Mode
33 1 0 = Standard
1 = MUX 32 Slave
2 = Siemens 3964
3 = Siemens RK512
Main Port Electrical
Interface
/Comms
/SerMain/Line
/MainHW
10 1 0 = RS232
1 = RS485 Full Duplex
MUX 32 protocol
address
/Comms
/SerMain/Line
/Addr
58 0 Range: 0 to 31
Handshake
(RS232)
/Comms
/SerMain/Line
/FlowCtrl
57 1 0 = None
1 = Hardware (RTS/CTS)
2 = Software (Xon/Xoff)
Handshake
(RS485)
/Comms
/SerMain/Line
/Flow485
60 1 0 = None
1 = Software (Xon/Xoff)
Baud Rate (Mux32
Slave)
/Comms
/SerMain/Line
/StdBaud
49 1 8 = 1200
1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
7 = 115200
Baud Rate (NOT
Mux32 Slave)
/Comms
/SerMain/Line
/MuxBaud
59 1 1 = 2400
2 = 4800
3 = 9600
4 = 19200
5 = 38400
6 = 57600
Parity /Comms
/SerMain/Line
/Parity
50 1 0 = None
1 = Odd
2 = Even
Data Bits /Comms
/SerMain/Line
/Data
51 1 0 = 7
1 = 8