APPENDIX
5
PARAMETER CONTROL RULES
Stop Phase Edge
(only for On Line 2
Input)
Must be ≠ Leading if
Extended Phase = Enable
ACK/NAK
Protocol
Not available if
Operating Mode Selection ≠ On Line.
Not available if
Scanner Cluster Topology Role = Slave
Synchronized.
Quality Counters
Not available if
Operating Mode Selection ≠ On Line and ≠
Automatic.
Not available if
Scanner Cluster Topology Role = Slave
Synchronized.
VERIFIER
Code Verifier
Not available if
Code Combination ≠ Single Label.
Not available if
Operating Mode Selection ≠ On Line and ≠
Automatic and ≠ Continuous.
READING SYSTEM LAYOUT
Device
Assignment
Must be ≠ Master RS232 (Type A) and ≠ Slave RS232 (Type A)
if
Auxiliary Serial Port Data TX = Enable.
Must be ≠ Master RS232 (Type A) and ≠ Slave RS232 (Type A)
if
Auxiliary Serial Port Pass Through = Enable.
DATA COMMUNICATION SETTING
Host Application
Protocol Type
Must be ≠ Crisplant if
Operating Mode Selection ≠ On Line.
Must be ≠ Crisplant if On Line Options = Serial On Line.
Must be ≠ Crisplant if
Main Port Communication Mode ≠
Standard.
Must be ≠ Crisplant if
Auxiliary Serial Port Pass Through =
Enable.
MAIN SERIAL PORT
Main Port
Communication
Mode
Must be = Standard if
Host Application Protocol Type ≠
Standard.
AUXILIARY SERIAL PORT
Data
Transmission
Must be = Disable if
Local Device Alternative Network Setting =
Master RS232 (Type A) or = Slave RS232 (Type A).
Pass Through
Must be = Disable if
Host Application Protocol Type ≠ Standard.
Must be = Disable if
Local Device Alternative Network Setting =
Master RS232 (Type A) or = Slave RS232 (Type A).