2KN FAMILY AND DS4800 PARAMETERS LIST
4
4.2 OPERATING MODES
PARAMETER COMPLETE PATH SHC PT VALUE
OPERATING MODES
Operating Mode
Selection
/Operating
/Selection
31 1 0 = On Line
1 = Automatic
4 = Continuous
3 = Test
On Line Options /Operating
/OnLOpt
73 1 0 = On Line 1 input
1 = On Line 2 input
2 = Serial On Line
Extended Phase /Operating
/ExtendedPhase
5115 1 0 = Disable
1 = Enable
Test Mode Data
Transmission
/Operating
/TestSend
500 1 0 = All Selected
Channels + ID-NET
(MULTIDATA)
1 = Aux
2 = Disable
3 = Main
4 = Main&Aux
Serial Start String /Operating
/SerialStart
86 3 Length: 1 to 32
Start Input Number /Operating
/ONLStartIn
74 0 Range: 1 to 2
Start Input Active
Level
/Operating
/ONLStartInLev
75 1 0 = Active Closed
1 = Active Open
Serial Stop String /Operating
/SerialStop
87 3 Length: 1 to 32
Stop Input Number /Operating
/ONLStopIn
76 0 Range: 1 to 2
Stop Input Active
Level
/Operating
/ONLStopInLev
77 1 0 = Active Closed
1 = Active Open
Stop Phase Edge /Operating
/PhaseOffLeadEdge
5120 1 0 = Trailing
1 = Leading
Reading Phase
Timeout
/Operating
/OnLTimOutEn
78 1 0 = Disable
1 = Enable
Timeout (ms) /Operating
/ONLTimeOut
79 0 Range: 40 to 15000
Timeout Counting
From
/Operating
/ONLToutStart
5119 1 0 = Start
1 = Stop
Stop Priority /Operating
/ONLStopPrio
80 1 0 = Input / SerialStop
1 = Always Timeout