2KN FAMILY AND DS4800 PARAMETERS LIST
4
PARAMETER COMPLETE PATH SHC PT VALUE
MAIN SERIAL PORT
Data TX /Comms
/SerMain
/SerMain
510 1 0 = Disable
1 = Enable
Heartbeat /Comms
/SerMain
/HeartbeatEnM
5069 0 = Disable
1 = Enable
Unconditioned
2 = Enable Conditioned
MAIN SERIAL PORT / HEARTBEAT
Timeout (s) /Comms
/SerMain/HeartbeatM
/TimeOutM
5079 0 Range: 1 to 3600
Heartbeat Header
String
/Comms
/SerMain/HeartbeatM
/HeaderM
5075 3 Length: 0 to 128
Heartbeat Fields
Separator String
/Comms
/SerMain/HeartbeatM
/SeparatorM
5076 3 Length: 0 to 128
Counter Module
(Maximum Counter
Value)
/Comms
/SerMain/HeartbeatM
/CounterModM
5071 1 0 = Disable
1 = 10
2 = 100
3 = 1000
4 = 10000
5 = Custom
Custom Counter
Module
/Comms
/SerMain/HeartbeatM
/CustomCounterModM
5073 0 Length: 2 to 10000
Counter Starting
Value
/Comms
/SerMain//HeartbeatM
/CounterStartM
5072 0 Length: 0 to 9999
Counter Direction /Comms
/SerMain/HeartbeatM
/CounterDirectionM
5070 1 0 = Up
1 = Down
System Diagnostics /Comms
/SerMain//HeartbeatM
/SysDiagM
5077 1 0 = Disable
1 = Enable
Network
Diagnostics
/Comms
/SerMain/HeartbeatM
/DevDiagM
5074 1 0 = Disable
1 = Enable
53