Datalogic DS4800 Manual de usuario Pagina 51

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 100
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 50
2KN FAMILY AND DS4800 PARAMETERS LIST
4
PARAMETER COMPLETE PATH SHC PT VALUE
Min Angle
(Degrees)
/Reading
/Oscillating4K
/MinAngle
5362 1 0 = -5
1 = -4.5
2 = -4
3 = -3.5
80 = 35
Max Angle
(Degrees)
/Reading
/Oscillating4K
/MaxAngle
5363 1 0 = -5
1 = -4.5
2 = -4
3 = -3.5
80 = 35
Frequency (Hz) /Reading
/Oscillating4K
/ContFreq
5364 1 1 = 0.1
2 = 0.2
5 = 0.5
7 = 0.7
10 = 1
15 = 1.5
20 = 2
25 = 2.5
30 = 3
35 = 3.5
40 = 4
45 =4.5
50 = 5
55 = 5.5
60 = 6
65 = 6.5
70 = 7
75 = 7.5
80 = 8
85 = 8.5
90 = 9
95 =9.5
100 = 10
Triggered /Reading
/Oscillating4K
/Triggered
5635 1 0 = Disable
1 = Enable
Second Zone
Trigger
/Reading
/Oscillating4K
/TriggerIn
5636 1 0 = Phase
1 = Input 1
2 = Input 2
45